UL,DLC Qualified 4FT Direct Replacment Ballast Compatible LED Tube (Bulk Sales)
Features:
Provides exceptional lighting, energy efficient, and low in maintenance cost. Environmentally friendly, contains no mercury and is recyclable. UL and DLC Certified qualifying for local energy company’s rebate programs.
Applications:
T8 Linear Tube retrofits are usually but not specifically used in commercial buildings such as hotels, conference rooms, schools, and office buildings.
Basic Feature
- T8 direct replacement ballast compatible led tubes are an energy saving product as special replacement for traditional flourescent T8 lamps.
- Designed to operate on existing all instant start ballast,rapid start ballast,programmed star ballast and emergency fixture with input voltage of AC120-277V, AC347V.
- This magic tubes minimize labor and recycling costs.
- THD less than 20%, Power factor more than 0.90.
- Reduces energy consumption up to 40%.
- Stable lumens output for different ballast brand with different ballast factor.
- No UV emission.
- This tube only work with ballast.
Detailed Data
- Wattage:18W/20W
- Life Span:50000 Hours
- Weight:360g
- Led Chip:SMD 2835
- Power Factor:More than 0.90
- Efficiency:120 lm/W
- Certificates:DLC,UL,cUL,NSF,Lighting Facts,RoHs
Installation Instruction
Prepair for Installation
- Check the ballast installed in the field and make sure the ballast is in manufacturer's ballast list. If the ballast out of the list, a test must needed before mass installation.
- Loose and damaged lamp holder and socket need to be adjusted or be replaced.
"Plug" and "Play" procedure
- Turn off the power to the light fixture at the breaker panel before installation.
- Open the diffuser from the light fixture.Ensure pins are firmly seated in lampholders.
- Remove the flourescent tubes, Please dispose of these items properly as they contain mercury.

- Put led tube into the lighting fixture.

- Install the Led tube,close the diffuser.
- Turn on the power.
Caution
- Use only with ballast.
- Risk of fire.Do not install this lamp in a pre-heat luminaire.
- Risk of electric shock.
- Use only in place of fluorescent lamps specified on label or as a retrofit kit.
- This lamp is not intended for use with emergency exists.
- These lamps are to be used in indoor damp location only.Do not suitable for wet location.
- These lamps are not to be used with a light dimmer.
- If the lamp or luminaire exhibits undesirable operation (Buzzing, Flickering, etc), immediately turn off power,remove lamp from
luminaire and contact manufacturer.
- This lamp only operates on electronic ballasts or without any ballast.If lamp does not light when the luminaire is energized,
remove this lamp from luminaire and contact manufacturer.